rockbox/firmware/target/arm/as3525/sansa-c200v2/powermgmt-c200v2.c
William Wilgus 4f3bbeaffc Remove BATTERY_TYPES
Change-Id: I4fa03a10d0032fd6f92722bbe1d4b7eec0b95cb4
2025-03-11 02:26:38 -04:00

50 lines
2 KiB
C

/***************************************************************************
* __________ __ ___.
* Open \______ \ ____ ____ | | _\_ |__ _______ ___
* Source | _// _ \_/ ___\| |/ /| __ \ / _ \ \/ /
* Jukebox | | ( <_> ) \___| < | \_\ ( <_> > < <
* Firmware |____|_ /\____/ \___ >__|_ \|___ /\____/__/\_ \
* \/ \/ \/ \/ \/
* $Id$
*
* Copyright (C) 2002 by Heikki Hannikainen, Uwe Freese
* Revisions copyright (C) 2005 by Gerald Van Baren
*
* This program is free software; you can redistribute it and/or
* modify it under the terms of the GNU General Public License
* as published by the Free Software Foundation; either version 2
* of the License, or (at your option) any later version.
*
* This software is distributed on an "AS IS" basis, WITHOUT WARRANTY OF ANY
* KIND, either express or implied.
*
****************************************************************************/
#include "config.h"
#include "powermgmt.h"
/*
* about 10%, calibrated with C240v2 battery profile at
* http://www.rockbox.org/wiki/bin/viewfile/Main/SansaRuntime?filename=c240v2_battery_bench_percent.png;rev=3
*/
unsigned short battery_level_disksafe = 3600;
unsigned short battery_level_shutoff = 3300;
/* voltages (millivolt) of 0%, 10%, ... 100% when charging disabled */
unsigned short percent_to_volt_discharge[11] =
{
/*
* Below table is calibrated according to
* http://www.rockbox.org/wiki/bin/viewfile/Main/SansaRuntime?filename=c240v2_battery_bench_percent.png;rev=3
* OF seems to stop charging at 4150mV, so that's 100% here.
*/
3300, 3597, 3674, 3719, 3745, 3776, 3825, 3890, 3954, 4035, 4150
};
/* voltages (millivolt) of 0%, 10%, ... 100% when charging enabled */
unsigned short percent_to_volt_charge[11] =
{
/* TODO: simple uncalibrated curve with 10% knee at 3.60V */
3400, 3600, 3670, 3740, 3810, 3880, 3950, 4020, 4090, 4160, 4230
};