Added battery profile change to correct file, removed unused powermgmt-as3525.c

git-svn-id: svn://svn.rockbox.org/rockbox/trunk@25541 a1c6a512-1295-4272-9138-f99709370657
This commit is contained in:
Tobias Diedrich 2010-04-08 19:31:03 +00:00
parent 12a6ef5c18
commit f7b0224a9c
2 changed files with 11 additions and 84 deletions

View file

@ -25,7 +25,11 @@
const unsigned short battery_level_dangerous[BATTERY_TYPES_COUNT] =
{
3400
/*
* about 10%, calibrated with C240v2 battery profile at
* http://www.rockbox.org/wiki/bin/viewfile/Main/SansaRuntime?filename=c240v2_battery_bench_percent.png;rev=3
*/
3600
};
const unsigned short battery_level_shutoff[BATTERY_TYPES_COUNT] =
@ -36,8 +40,12 @@ const unsigned short battery_level_shutoff[BATTERY_TYPES_COUNT] =
/* voltages (millivolt) of 0%, 10%, ... 100% when charging disabled */
const unsigned short percent_to_volt_discharge[BATTERY_TYPES_COUNT][11] =
{
/* TODO: calibrate, copied from powermgmt-c200.c svn r22636 */
{ 3400, 3689, 3744, 3773, 3798, 3831, 3886, 3947, 4005, 4102, 4220 },
/*
* Below table is calibrated according to
* http://www.rockbox.org/wiki/bin/viewfile/Main/SansaRuntime?filename=c240v2_battery_bench_percent.png;rev=3
* OF seems to stop charging at 4150mV, so that's 100% here.
*/
{ 3300, 3597, 3674, 3719, 3745, 3776, 3825, 3890, 3954, 4035, 4150 }
};
/* voltages (millivolt) of 0%, 10%, ... 100% when charging enabled */