mirror of
https://github.com/Rockbox/rockbox.git
synced 2025-10-13 18:17:39 -04:00
FS#13538 export and import battery level tables
when battery_bench is run exports a file in the rockbox directory called 'battery_levels.default' if the user wants their own levels they can rename the file battery_levels.cfg and it will be loaded at boot some minimal error checking is performed prior to using the values added manual entry Change-Id: Ia0126faced0c7229fcf8385a1bcb584b5a9dc378
This commit is contained in:
parent
3539dd5a70
commit
10f8312db4
79 changed files with 611 additions and 298 deletions
|
@ -102,13 +102,13 @@ static void battery_status_update(void)
|
|||
batt_current = charging ? BATT_CHARGE_STEP : BATT_DISCHARGE_STEP;
|
||||
}
|
||||
|
||||
const unsigned short battery_level_dangerous[BATTERY_TYPES_COUNT] = { 3200 };
|
||||
const unsigned short battery_level_shutoff[BATTERY_TYPES_COUNT] = { 3200 };
|
||||
unsigned short battery_level_disksafe[BATTERY_TYPES_COUNT] = { 3200 };
|
||||
unsigned short battery_level_shutoff[BATTERY_TYPES_COUNT] = { 3200 };
|
||||
|
||||
/* make the simulated curve nicely linear */
|
||||
const unsigned short percent_to_volt_discharge[BATTERY_TYPES_COUNT][11] =
|
||||
unsigned short percent_to_volt_discharge[BATTERY_TYPES_COUNT][11] =
|
||||
{ { 3300, 3400, 3500, 3600, 3700, 3800, 3900, 4000, 4100, 4200, 4300 } };
|
||||
const unsigned short percent_to_volt_charge[11] =
|
||||
unsigned short percent_to_volt_charge[11] =
|
||||
{ 3300, 3400, 3500, 3600, 3700, 3800, 3900, 4000, 4100, 4200, 4300 };
|
||||
|
||||
#if CONFIG_BATTERY_MEASURE & VOLTAGE_MEASURE
|
||||
|
|