mirror of
https://github.com/Rockbox/rockbox.git
synced 2025-11-09 13:12:37 -05:00
FS#13538 export and import battery level tables
when battery_bench is run exports a file in the rockbox directory called 'battery_levels.default' if the user wants their own levels they can rename the file battery_levels.cfg and it will be loaded at boot some minimal error checking is performed prior to using the values added manual entry Change-Id: Ia0126faced0c7229fcf8385a1bcb584b5a9dc378
This commit is contained in:
parent
3539dd5a70
commit
10f8312db4
79 changed files with 611 additions and 298 deletions
|
|
@ -21,25 +21,25 @@
|
|||
#include "power.h"
|
||||
#include "power-xduoo.h"
|
||||
|
||||
const unsigned short battery_level_dangerous[BATTERY_TYPES_COUNT] =
|
||||
unsigned short battery_level_disksafe[BATTERY_TYPES_COUNT] =
|
||||
{
|
||||
3443 /* 5% */
|
||||
};
|
||||
|
||||
/* the OF shuts down at this voltage */
|
||||
const unsigned short battery_level_shutoff[BATTERY_TYPES_COUNT] =
|
||||
unsigned short battery_level_shutoff[BATTERY_TYPES_COUNT] =
|
||||
{
|
||||
3400
|
||||
};
|
||||
|
||||
/* voltages (millivolt) of 0%, 10%, ... 100% when charging disabled */
|
||||
const unsigned short percent_to_volt_discharge[BATTERY_TYPES_COUNT][11] =
|
||||
unsigned short percent_to_volt_discharge[BATTERY_TYPES_COUNT][11] =
|
||||
{
|
||||
{ 3400, 3498, 3560, 3592, 3624, 3672, 3753, 3840, 3937, 4047, 4189 }
|
||||
};
|
||||
|
||||
/* voltages (millivolt) of 0%, 10%, ... 100% when charging enabled */
|
||||
const unsigned short percent_to_volt_charge[11] =
|
||||
unsigned short percent_to_volt_charge[11] =
|
||||
{
|
||||
3485, 3780, 3836, 3857, 3890, 3930, 3986, 4062, 4158, 4185, 4196
|
||||
};
|
||||
|
|
|
|||