mirror of
https://github.com/Rockbox/rockbox.git
synced 2025-11-09 13:12:37 -05:00
FS#13538 export and import battery level tables
when battery_bench is run exports a file in the rockbox directory called 'battery_levels.default' if the user wants their own levels they can rename the file battery_levels.cfg and it will be loaded at boot some minimal error checking is performed prior to using the values added manual entry Change-Id: Ia0126faced0c7229fcf8385a1bcb584b5a9dc378
This commit is contained in:
parent
3539dd5a70
commit
10f8312db4
79 changed files with 611 additions and 298 deletions
|
|
@ -56,19 +56,19 @@ void max17040_close(void)
|
|||
}
|
||||
|
||||
#if (CONFIG_BATTERY_MEASURE & VOLTAGE_MEASURE) == VOLTAGE_MEASURE
|
||||
const unsigned short battery_level_dangerous[BATTERY_TYPES_COUNT] =
|
||||
unsigned short battery_level_disksafe[BATTERY_TYPES_COUNT] =
|
||||
{
|
||||
3470
|
||||
};
|
||||
|
||||
/* the OF shuts down at this voltage */
|
||||
const unsigned short battery_level_shutoff[BATTERY_TYPES_COUNT] =
|
||||
unsigned short battery_level_shutoff[BATTERY_TYPES_COUNT] =
|
||||
{
|
||||
3450
|
||||
};
|
||||
|
||||
/* voltages (millivolt) of 0%, 10%, ... 100% when charging disabled */
|
||||
const unsigned short percent_to_volt_discharge[BATTERY_TYPES_COUNT][11] =
|
||||
unsigned short percent_to_volt_discharge[BATTERY_TYPES_COUNT][11] =
|
||||
{
|
||||
{ 3450, 3502, 3550, 3587, 3623, 3669, 3742, 3836, 3926, 4026, 4200 }
|
||||
};
|
||||
|
|
@ -76,7 +76,7 @@ const unsigned short percent_to_volt_discharge[BATTERY_TYPES_COUNT][11] =
|
|||
|
||||
#if CONFIG_CHARGING
|
||||
/* voltages (millivolt) of 0%, 10%, ... 100% when charging enabled */
|
||||
const unsigned short percent_to_volt_charge[11] =
|
||||
unsigned short percent_to_volt_charge[11] =
|
||||
{
|
||||
3450, 3670, 3721, 3751, 3782, 3821, 3876, 3941, 4034, 4125, 4200
|
||||
};
|
||||
|
|
|
|||
Loading…
Add table
Add a link
Reference in a new issue