FS#13538 export and import battery level tables
when battery_bench is run exports a file in the rockbox directory called 'battery_levels.default' if the user wants their own levels they can rename the file battery_levels.cfg and it will be loaded at boot some minimal error checking is performed prior to using the values added manual entry Change-Id: Ia0126faced0c7229fcf8385a1bcb584b5a9dc378
This commit is contained in:
parent
3539dd5a70
commit
10f8312db4
79 changed files with 611 additions and 298 deletions
|
|
@ -30,25 +30,25 @@ int _battery_voltage(void)
|
|||
|
||||
/* FIXME - next 4 functions taken from e200 - last 2 will need
|
||||
to be updated */
|
||||
const unsigned short battery_level_dangerous[BATTERY_TYPES_COUNT] =
|
||||
unsigned short battery_level_disksafe[BATTERY_TYPES_COUNT] =
|
||||
{
|
||||
3400
|
||||
};
|
||||
|
||||
const unsigned short battery_level_shutoff[BATTERY_TYPES_COUNT] =
|
||||
unsigned short battery_level_shutoff[BATTERY_TYPES_COUNT] =
|
||||
{
|
||||
3300
|
||||
};
|
||||
|
||||
/* voltages (millivolt) of 0%, 10%, ... 100% when charging disabled */
|
||||
const unsigned short percent_to_volt_discharge[BATTERY_TYPES_COUNT][11] =
|
||||
unsigned short percent_to_volt_discharge[BATTERY_TYPES_COUNT][11] =
|
||||
{
|
||||
/* Sansa Li Ion 750mAH FIXME */
|
||||
{ 3300, 3680, 3740, 3760, 3780, 3810, 3870, 3930, 3970, 4070, 4160 },
|
||||
};
|
||||
|
||||
/* voltages (millivolt) of 0%, 10%, ... 100% when charging enabled */
|
||||
const unsigned short percent_to_volt_charge[11] =
|
||||
unsigned short percent_to_volt_charge[11] =
|
||||
{
|
||||
/* Sansa Li Ion 750mAH FIXME */
|
||||
3300, 3680, 3740, 3760, 3780, 3810, 3870, 3930, 3970, 4070, 4160
|
||||
|
|
|
|||