mirror of
https://github.com/Rockbox/rockbox.git
synced 2025-11-09 13:12:37 -05:00
FS#13538 export and import battery level tables
when battery_bench is run exports a file in the rockbox directory called 'battery_levels.default' if the user wants their own levels they can rename the file battery_levels.cfg and it will be loaded at boot some minimal error checking is performed prior to using the values added manual entry Change-Id: Ia0126faced0c7229fcf8385a1bcb584b5a9dc378
This commit is contained in:
parent
3539dd5a70
commit
10f8312db4
79 changed files with 611 additions and 298 deletions
|
|
@ -25,24 +25,24 @@
|
|||
#include "adc.h"
|
||||
#include "powermgmt.h"
|
||||
|
||||
const unsigned short battery_level_dangerous[BATTERY_TYPES_COUNT] =
|
||||
unsigned short battery_level_disksafe[BATTERY_TYPES_COUNT] =
|
||||
{
|
||||
3515
|
||||
};
|
||||
|
||||
const unsigned short battery_level_shutoff[BATTERY_TYPES_COUNT] =
|
||||
unsigned short battery_level_shutoff[BATTERY_TYPES_COUNT] =
|
||||
{
|
||||
3486
|
||||
};
|
||||
|
||||
/* voltages (millivolt) of 0%, 10%, ... 100% when charging disabled */
|
||||
const unsigned short percent_to_volt_discharge[BATTERY_TYPES_COUNT][11] =
|
||||
unsigned short percent_to_volt_discharge[BATTERY_TYPES_COUNT][11] =
|
||||
{
|
||||
{ 3474, 3515, 3556, 3597, 3638, 3679, 3720, 3761, 3802, 3843, 3884 }
|
||||
};
|
||||
|
||||
/* voltages (millivolt) of 0%, 10%, ... 100% when charging enabled */
|
||||
const unsigned short percent_to_volt_charge[11] =
|
||||
unsigned short percent_to_volt_charge[11] =
|
||||
{
|
||||
3474, 3515, 3556, 3597, 3638, 3679, 3720, 3761, 3802, 3843, 3884
|
||||
};
|
||||
|
|
|
|||
Loading…