mirror of
https://github.com/FreeRTOS/FreeRTOS-Kernel.git
synced 2025-04-20 05:21:59 -04:00
Minor updates to the MSP430X CCS4 demo application.
This commit is contained in:
parent
2b92b7a5d9
commit
1b96233cf1
|
@ -111,11 +111,11 @@ to exclude the API function. */
|
|||
|
||||
/* The MSP430X port uses a callback function to configure its tick interrupt.
|
||||
This allows the application to choose the tick interrupt source.
|
||||
configTICK_INTERRUPT_VECTOR must also be set in FreeRTOSConfig.h to the correct
|
||||
interrupt vector for the chosen tick interrupt source. This implementation of
|
||||
configTICK_VECTOR must also be set in FreeRTOSConfig.h to the correct interrupt
|
||||
vector for the chosen tick interrupt source. This implementation of
|
||||
vApplicationSetupTimerInterrupt() generates the tick from timer A0, so in this
|
||||
case configTICK_INTERRUPT_VECTOR is set to TIMER0_A0_VECTOR. */
|
||||
#define configTICK_INTERRUPT_VECTOR TIMER0_A0_VECTOR
|
||||
case configTICK_VECTOR is set to TIMER0_A0_VECTOR. */
|
||||
#define configTICK_VECTOR TIMER0_A0_VECTOR
|
||||
|
||||
extern void vConfigureTimerForRunTimeStats( void );
|
||||
extern unsigned long ulGetRunTimeStatsTime( void );
|
||||
|
|
|
@ -183,6 +183,9 @@ information. */
|
|||
|
||||
/* The maximum number of lines of text that can be displayed on the LCD. */
|
||||
#define mainMAX_LCD_LINES ( 8 )
|
||||
|
||||
/* Just used to ensure parameters are passed into tasks correctly. */
|
||||
#define mainTASK_PARAMETER_CHECK_VALUE ( ( void * ) 0xDEAD )
|
||||
/*-----------------------------------------------------------*/
|
||||
|
||||
/*
|
||||
|
@ -265,7 +268,7 @@ void main( void )
|
|||
|
||||
/* Create the LCD, button poll and register test tasks, as described at
|
||||
the top of this file. */
|
||||
xTaskCreate( prvLCDTask, ( signed char * ) "LCD", configMINIMAL_STACK_SIZE * 2, NULL, mainLCD_TASK_PRIORITY, NULL );
|
||||
xTaskCreate( prvLCDTask, ( signed char * ) "LCD", configMINIMAL_STACK_SIZE * 2, mainTASK_PARAMETER_CHECK_VALUE, mainLCD_TASK_PRIORITY, NULL );
|
||||
xTaskCreate( prvButtonPollTask, ( signed char * ) "BPoll", configMINIMAL_STACK_SIZE, NULL, tskIDLE_PRIORITY, NULL );
|
||||
xTaskCreate( vRegTest1Task, ( signed char * ) "Reg1", configMINIMAL_STACK_SIZE, NULL, 0, NULL );
|
||||
xTaskCreate( vRegTest2Task, ( signed char * ) "Reg2", configMINIMAL_STACK_SIZE, NULL, 0, NULL );
|
||||
|
@ -305,6 +308,14 @@ unsigned char ucLine = 1;
|
|||
printf( "%d bytes of heap space remain unallocated\n", ( int ) xPortGetFreeHeapSize() );
|
||||
fflush( stdout );
|
||||
|
||||
/* Just as a test of the port, and for no functional reason, check the task
|
||||
parameter contains its expected value. */
|
||||
if( pvParameters != mainTASK_PARAMETER_CHECK_VALUE )
|
||||
{
|
||||
halLcdPrintLine( "Invalid parameter", ucLine, OVERWRITE_TEXT );
|
||||
ucLine++;
|
||||
}
|
||||
|
||||
for( ;; )
|
||||
{
|
||||
/* Wait for a message to be received. Using portMAX_DELAY as the block
|
||||
|
|
Loading…
Reference in a new issue