forked from len0rd/rockbox
Added battery profile change to correct file, removed unused powermgmt-as3525.c
git-svn-id: svn://svn.rockbox.org/rockbox/trunk@25541 a1c6a512-1295-4272-9138-f99709370657
This commit is contained in:
parent
12a6ef5c18
commit
f7b0224a9c
2 changed files with 11 additions and 84 deletions
|
@ -1,81 +0,0 @@
|
|||
/***************************************************************************
|
||||
* __________ __ ___.
|
||||
* Open \______ \ ____ ____ | | _\_ |__ _______ ___
|
||||
* Source | _// _ \_/ ___\| |/ /| __ \ / _ \ \/ /
|
||||
* Jukebox | | ( <_> ) \___| < | \_\ ( <_> > < <
|
||||
* Firmware |____|_ /\____/ \___ >__|_ \|___ /\____/__/\_ \
|
||||
* \/ \/ \/ \/ \/
|
||||
* $Id$
|
||||
*
|
||||
* Copyright © 2008 Rafaël Carré
|
||||
*
|
||||
* This program is free software; you can redistribute it and/or
|
||||
* modify it under the terms of the GNU General Public License
|
||||
* as published by the Free Software Foundation; either version 2
|
||||
* of the License, or (at your option) any later version.
|
||||
*
|
||||
* This software is distributed on an "AS IS" basis, WITHOUT WARRANTY OF ANY
|
||||
* KIND, either express or implied.
|
||||
*
|
||||
****************************************************************************/
|
||||
|
||||
#include "config.h"
|
||||
#include "adc.h"
|
||||
#include "adc-target.h"
|
||||
#include "powermgmt.h"
|
||||
|
||||
/* TODO
|
||||
Each as3525 target should probably define its own battery properties
|
||||
(dangerous/shutoff battery level, discharge/charge curves) in a file
|
||||
called powermgmt-<target>.c in its own sub-directory.
|
||||
|
||||
For now, this file provides simple uncalibrated settings to get at least
|
||||
a basic reading for all as3525 targets with a lithium battery.
|
||||
*/
|
||||
|
||||
const unsigned short battery_level_dangerous[BATTERY_TYPES_COUNT] =
|
||||
{
|
||||
/*
|
||||
* about 10%, calibrated with C240v2 battery profile at
|
||||
* http://www.rockbox.org/wiki/bin/viewfile/Main/SansaRuntime?filename=c240v2_battery_bench_percent.png;rev=1
|
||||
*/
|
||||
3600
|
||||
};
|
||||
|
||||
const unsigned short battery_level_shutoff[BATTERY_TYPES_COUNT] =
|
||||
{
|
||||
3300
|
||||
};
|
||||
|
||||
/* voltages (millivolt) of 0%, 10%, ... 100% when charging disabled */
|
||||
const unsigned short percent_to_volt_discharge[BATTERY_TYPES_COUNT][11] =
|
||||
{
|
||||
/*
|
||||
* TODO:
|
||||
* Below table is calibrated for C240v2 according to
|
||||
* http://www.rockbox.org/wiki/bin/viewfile/Main/SansaRuntime?filename=c240v2_battery_bench_percent.png;rev=1
|
||||
* Batteries for other models may have different discharging curves.
|
||||
* OF seems to stop charging at 4150mV, so that's 100% here.
|
||||
*/
|
||||
{ 3300, 3597, 3674, 3719, 3745, 3776, 3825, 3890, 3954, 4035, 4150 }
|
||||
};
|
||||
|
||||
#if CONFIG_CHARGING
|
||||
/* voltages (millivolt) of 0%, 10%, ... 100% when charging enabled */
|
||||
const unsigned short percent_to_volt_charge[11] =
|
||||
{
|
||||
/* TODO: simple uncalibrated curve, linear except for first 10% */
|
||||
3300, 3390, 3480, 3570, 3660, 3750, 3840, 3930, 4020, 4110, 4200
|
||||
};
|
||||
#endif /* CONFIG_CHARGING */
|
||||
|
||||
/* ADC should read 0x3ff=5.12V */
|
||||
#define BATTERY_SCALE_FACTOR 5125
|
||||
/* full-scale ADC readout (2^10) in millivolt */
|
||||
|
||||
/* Returns battery voltage from ADC [millivolts] */
|
||||
unsigned int battery_adc_voltage(void)
|
||||
{
|
||||
return (adc_read(ADC_RTCSUP) * BATTERY_SCALE_FACTOR) >> 10;
|
||||
}
|
||||
|
|
@ -25,7 +25,11 @@
|
|||
|
||||
const unsigned short battery_level_dangerous[BATTERY_TYPES_COUNT] =
|
||||
{
|
||||
3400
|
||||
/*
|
||||
* about 10%, calibrated with C240v2 battery profile at
|
||||
* http://www.rockbox.org/wiki/bin/viewfile/Main/SansaRuntime?filename=c240v2_battery_bench_percent.png;rev=3
|
||||
*/
|
||||
3600
|
||||
};
|
||||
|
||||
const unsigned short battery_level_shutoff[BATTERY_TYPES_COUNT] =
|
||||
|
@ -36,8 +40,12 @@ const unsigned short battery_level_shutoff[BATTERY_TYPES_COUNT] =
|
|||
/* voltages (millivolt) of 0%, 10%, ... 100% when charging disabled */
|
||||
const unsigned short percent_to_volt_discharge[BATTERY_TYPES_COUNT][11] =
|
||||
{
|
||||
/* TODO: calibrate, copied from powermgmt-c200.c svn r22636 */
|
||||
{ 3400, 3689, 3744, 3773, 3798, 3831, 3886, 3947, 4005, 4102, 4220 },
|
||||
/*
|
||||
* Below table is calibrated according to
|
||||
* http://www.rockbox.org/wiki/bin/viewfile/Main/SansaRuntime?filename=c240v2_battery_bench_percent.png;rev=3
|
||||
* OF seems to stop charging at 4150mV, so that's 100% here.
|
||||
*/
|
||||
{ 3300, 3597, 3674, 3719, 3745, 3776, 3825, 3890, 3954, 4035, 4150 }
|
||||
};
|
||||
|
||||
/* voltages (millivolt) of 0%, 10%, ... 100% when charging enabled */
|
||||
|
|