forked from len0rd/rockbox
powermgmt: Add battery current measurement
This allows targets to report the actual discharging or charging current if they are able to. Change-Id: I0b538e6ac94346f1434e45f83c8da8c1260a53a3
This commit is contained in:
parent
923f92cb12
commit
ad05c872fe
4 changed files with 52 additions and 8 deletions
|
@ -110,7 +110,8 @@ static int percent_now; /* Cached to avoid polling too often */
|
|||
#if !(CONFIG_BATTERY_MEASURE & TIME_MEASURE)
|
||||
int _battery_time(void) { return -1; }
|
||||
#endif
|
||||
#if (CONFIG_BATTERY_MEASURE & TIME_MEASURE) || defined(CURRENT_NORMAL)
|
||||
#if (CONFIG_BATTERY_MEASURE & TIME_MEASURE) || \
|
||||
defined(CURRENT_NORMAL) || (CONFIG_BATTERY_MEASURE & CURRENT_MEASURE)
|
||||
static int time_now; /* Cached to avoid polling too often */
|
||||
#endif
|
||||
|
||||
|
@ -121,6 +122,12 @@ int _battery_voltage(void) { return -1; }
|
|||
static int voltage_avg, voltage_now;
|
||||
#endif
|
||||
|
||||
#if !(CONFIG_BATTERY_MEASURE & CURRENT_MEASURE)
|
||||
int _battery_current(void) { return -1; }
|
||||
#else
|
||||
static int current_avg, current_now;
|
||||
#endif
|
||||
|
||||
/* The battery level can be obtained in two ways. If the target reports
|
||||
* voltage, the battery level can be estminated using percent_to_volt_*
|
||||
* curves. If the target can report the percentage directly, then that
|
||||
|
@ -142,7 +149,8 @@ int battery_level(void)
|
|||
* on the battery level and the actual current usage. */
|
||||
int battery_time(void)
|
||||
{
|
||||
#if (CONFIG_BATTERY_MEASURE & TIME_MEASURE) || defined(CURRENT_NORMAL)
|
||||
#if (CONFIG_BATTERY_MEASURE & TIME_MEASURE) || \
|
||||
defined(CURRENT_NORMAL) || (CONFIG_BATTERY_MEASURE & CURRENT_MEASURE)
|
||||
return time_now;
|
||||
#else
|
||||
return -1;
|
||||
|
@ -166,7 +174,9 @@ int battery_voltage(void)
|
|||
* the power consumed by the backlight, remote display, SPDIF, etc. */
|
||||
int battery_current(void)
|
||||
{
|
||||
#if defined(CURRENT_NORMAL)
|
||||
#if CONFIG_BATTERY_MEASURE & CURRENT_MEASURE
|
||||
return current_now;
|
||||
#elif defined(CURRENT_NORMAL)
|
||||
int current = CURRENT_NORMAL;
|
||||
|
||||
#ifndef BOOTLOADER
|
||||
|
@ -223,8 +233,8 @@ int battery_current(void)
|
|||
#endif
|
||||
}
|
||||
|
||||
/* Initialize the battery voltage filter. This is called once
|
||||
* by the power thread before entering the main polling loop. */
|
||||
/* Initialize the battery voltage/current filters. This is called
|
||||
* once by the power thread before entering the main polling loop. */
|
||||
static void average_init(void)
|
||||
{
|
||||
#if CONFIG_BATTERY_MEASURE & VOLTAGE_MEASURE
|
||||
|
@ -244,9 +254,14 @@ static void average_init(void)
|
|||
|
||||
voltage_avg = voltage_now * BATT_AVE_SAMPLES;
|
||||
#endif /* CONFIG_BATTERY_MEASURE & VOLTAGE_MEASURE */
|
||||
|
||||
#if CONFIG_BATTERY_MEASURE & CURRENT_MEASURE
|
||||
current_now = _battery_current();
|
||||
current_avg = current_now * BATT_CURRENT_AVE_SAMPLES;
|
||||
#endif
|
||||
}
|
||||
|
||||
/* Sample the battery voltage and update the filter.
|
||||
/* Sample the battery voltage/current and update the filters.
|
||||
* Updated once every POWER_THREAD_STEP_TICKS. */
|
||||
static void average_step(bool low_battery)
|
||||
{
|
||||
|
@ -262,6 +277,11 @@ static void average_step(bool low_battery)
|
|||
#else
|
||||
(void)low_battery;
|
||||
#endif
|
||||
|
||||
#if CONFIG_BATTERY_MEASURE & CURRENT_MEASURE
|
||||
current_avg += _battery_current() - current_avg / BATT_CURRENT_AVE_SAMPLES;
|
||||
current_now = current_avg / BATT_CURRENT_AVE_SAMPLES;
|
||||
#endif
|
||||
}
|
||||
|
||||
/* Send system battery level update events on reaching certain significant
|
||||
|
@ -353,7 +373,7 @@ static void battery_status_update(void)
|
|||
|
||||
#if CONFIG_BATTERY_MEASURE & TIME_MEASURE
|
||||
time_now = _battery_time();
|
||||
#elif defined(CURRENT_NORMAL)
|
||||
#elif defined(CURRENT_NORMAL) || (CONFIG_BATTERY_MEASURE & CURRENT_MEASURE)
|
||||
int current = battery_current();
|
||||
if(level >= 0 && current > 0 && battery_capacity > 0) {
|
||||
#if CONFIG_CHARGING >= CHARGING_MONITOR
|
||||
|
@ -455,6 +475,11 @@ void reset_battery_filter(int millivolts)
|
|||
{
|
||||
voltage_avg = millivolts * BATT_AVE_SAMPLES;
|
||||
voltage_now = millivolts;
|
||||
#if CONFIG_BATTERY_MEASURE & CURRENT_MEASURE
|
||||
/* current would probably be inaccurate too */
|
||||
current_now = _battery_current();
|
||||
current_avg = current_now * BATT_CURRENT_AVE_SAMPLES;
|
||||
#endif
|
||||
battery_status_update();
|
||||
}
|
||||
#endif /* HAVE_BATTERY_SWITCH */
|
||||
|
@ -589,7 +614,6 @@ static inline bool detect_charger(unsigned int pwr)
|
|||
}
|
||||
#endif /* CONFIG_CHARGING */
|
||||
|
||||
|
||||
#if CONFIG_BATTERY_MEASURE & VOLTAGE_MEASURE
|
||||
static int power_hist_item(void)
|
||||
{
|
||||
|
|
Loading…